Menvier ts690 user manual


















Page Unsetting After An Alarm Unsetting After an Alarm If an alarm has occurred whilst the alarm system is full or part set, the display will indicate the detection circuit that was triggered when you unset the system. User Reset If your system has been programmed as user reset, alarms can be reset by any user that has a valid passcode. To silence the beeps enter your passcode. Contact your alarm company: Remote Reset If your system is programmed as remote reset, alarms can be reset by your alarm company or via the exchange or unique passcodes.

There are 12 menu options and access to these options will depend on your access level. User menu Page Bell Test Bell Test This option allows you to periodically test the external sounders bell and strobe and internal sounders. When selected each device will operate in sequence for nine seconds. Page Walk Test Walk Test This option allows you to test the function of individual detection circuits without causing an alarm.

Once the test has been completed the tested circuits can be reviewed in numerical order. Press [ESC] to leave the walk test option and return to user menu 1. To return the system to the open mode press [ESC]. This option allows you to select one of the four chime options: 1 Disabled Chime circuits are disabled.

Once a shunt group has been defined this option allows the you isolate and re-instate the circuits that are assigned to the shunt group. Page Omit Circuits Omit Circuits Occasionally it may be necessary to omit detection circuits when setting or part setting the system. This allows the user access to the omitted area s when the system is set or part set. It is also possible to omit 24hr or Auxiliary circuits so that access to these areas can be obtained when the system is unset.

Page 22 Omit Circuits Cont. From the unset open mode enter your passcode and press [ENT] to select user menu 1. Whilst user menu 1 is selected. Press [7] to select the omit circuits option. Select the circuit you require to omit by either entering the circuit number or by using the [A] and [C] keys to scroll up and down through the circuits. Press [8] to select the silent set option. Press [0] to silent full set , [A], [B] or [C] for silent part set. There are 10 menu options and access to these options will depend on your access level.

Page View Circuits View Circuits This option allows you to ascertain the status of each detection circuit, The status for each circuit may be as follows: Healthy The normal status of a detection circuit, i. Active This is the alarm status of a detection circuit, i. Tamper This is the tamper open circuit status of a detection circuit, i. The clock is used for providing event times in the event log and is also displayed when the system is unset or full set.

User 01 is the master user which has a default setting of Page 29 Setup New Users Cont. Capable of switching With the ID loop still disconnected from the control panel, use a DVM to measure the To power the system for the first time: resistance between the following cores and 1. Page Program Circuits Program Circuits [1. Each circuit must be A circuit that is normally connected to a push When assigned to a 24 Hour This timer has a working a working range of - Whe n format.

The circuit status conditions The passcode. The default passcode is but the Page Configure Part Sets [2. The central station A Typical 3 Bedroom House The alarm abort bedroom house. Press [9] Display shows last event 5. Press [A] for earlier events, [C] for later events, [B] to display time of event, then [B] again for date of event 6.

Press [ESC] Display shows 2- 7. Press [ESC] Display shows 1- 8. Press [2] Display shows 5. Enter [time in 24 hour format] Display shows new time 6.

Press [ENT] Display shows 2- 7. Press [3] Display shows 8. Enter [ddmm] Display shows new date no years 9. Press [ENT] Display shows 2- Back to Index. Full set the system. Part set the system. Unset the system. Reset system after alarm condition. Remote reset after alarm condition. Omit a zone. Press [ENT] to move to next zone, optionally pressing [0] to toggle zone as omitted.